XU Jingwei, MA Shangguo, WANG Lisi. Welding procedure analysis of main coolant line in VVER-1000[J]. Eletric Welding Machine2021, 51(2): 83-87.DOI: 10.7512/j.issn.1001-2303.2021.02.16.
The material of VVER-1000 MCL(main coolant line in nuclear power plant connects with reactor pressure vessel
steam generator and reactor coolant pump
thus constituting the primary loop pressure boundary) is the composite pipe with large thickness and dissimilar metal. Welding procedure of VVER-1000 MCL is complex
and the welding shrinkage is difficult to control. In this article
starting from the selection of welding material
formulation of welding parameters and other aspects
an effective and reasonable welding procedure is analyzed scientifically and formulated to ensure the welding quality.